Mitsubishi Electric HVAC - M-Series Heat Pumps - Indoor Units (Multi Zone)_MSZ-MSZ-FE09NA-8

M-Series Heat Pumps - Indoor Units (Multi Zone)_MSZ Model Number: #MSZ-FE09NA-8 Slim, wall-mounted indoor units provide zone comfort control. INVERTER-driven compressors and electronic LEV's provide higher efficiency with controlled power usage. The outdoor unit powers the indoor unit, and should...


MasterFormat: Decentralized HVAC Equipment | Decentralized Unitary HVAC Equipment



Mitsubishi Electric HVAC
3400 Lawrenceville Suwanee Rd.
Suwanee, GA 30024
Tel: (800) 687-1966
Fax: (800) 658-1458

http://www.mehvac.com

Request More Info

DOWNLOADS

Related Products

Overview



M-Series Heat Pumps - Indoor Units (Multi Zone)_MSZ - MSZ-FE09NA-8

M-Series Heat Pumps - Indoor Units (Multi Zone)_MSZ


Model Number: #MSZ-FE09NA-8

Slim, wall-mounted indoor units provide zone comfort control. INVERTER-driven compressors and electronic LEV's provide higher efficiency with controlled power usage. The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restored when power returns.


Features
  • Sleek, flat panel design
  • Hot-start technology
  • Quiet operation
  • i-see Sensor technology available
  • Enhanced filtration system available
  • Hand-held wireless remote; optional MHK1 backlit wall-mounted wireless remote controller


Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 9000 Btu/h (2.64 kW) *1
Cooling Capacity Range 2800 - 9000 BTU/h (0.8 - 2.6 kW)
Cooling Total Input 580 W (0.6 kW)
Cooling Energy Efficiency SEER 26
Cooling Sensible Heat Factor 0.76
Cooling Moisture Removal Pints/H 2.1
Cooling EER 15.5
Heating at 47° F Rated Capacity 10900 Btu/h (3.2 kW) *2
Heating at 47° F Capacity Range 3000 - 18000 Btu/h (0.9 - 5.3 kW)
Heating at 47° F Total Input 710 (150 - 2250) W
Heating at 47° F HSPF (Region IV) 10
Heating at 47° F COP 4.5
Heating at 17° F Maximum Capacity 12500 Btu/h (3.7 kW)
Heating at 17° F COP 3.02 Btu/Btu
Heating at 17° F Total Input 650 W
Heating at 17° F Rated Capacity 6700 Btu/h (2 kW) *3
Heating at 5° F Maximum Capacity 10900 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Fan Fan Motor - F.L.A. 0.76 F.L.A
Airflow Cooling : DRY 162-226-339-381 CFM (4-6-9-10 m³/min)
Airflow Cooling : WET 144-202-307-343 CFM (4-6-9-10 m³/min)
Airflow Heating : WET 166-240-367-381 CFM (5-7-10-11 m³/min)
Sound Pressure Level Cooling 22-31-39-42 dB(A)
Sound Pressure Level Heating 22-31-40-42 dB(A)
Dimensions H x W x D Height 11-5/8 Inches (295 mm)
Dimensions H x W x D Width 31-3/8 Inches (799 mm)
Dimensions H x W x D Depth 10-1/8 Inches (257 mm)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Refrigerant Pipe Size O.D. Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - WB 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - WB 57°F (14°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Maximum - DB 80°F (27°C) DB, 67°F (19°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - WB 60°F (16°C) WB
Operation Conditions - Indoor Intake Air Temperature Heating - Minimum - DB 70°F (21°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Minimum - DB 67°F (19°C) DB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum -WB 73°F (23°C) WB
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB 90°F (32°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB , WB -13°F (-25°C) DB, -15°F (-26°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - WB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - WB -15°F (-26°C) WB
Operation Conditions - Outdoor Intake Air Temperature Heating - Minimum - DB -13°F (-25°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - WB 65°F (18°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB 115°F (46°C) DB
Operation Conditions - Outdoor Intake Air Temperature Cooling- Minimum - DB 14°F (-10°C) DB
Operation Conditions - Outdoor Intake Air Temperature Heating - Maximum - DB 75°F (24°C) DB
Voltage Indoor - Outdoor S2-S3 DC 12-24V
Voltage Indoor - Outdoor S1-S2 AC 208 / 230V
External Finish Munsell 1.0Y 9.2 / 0.2