CITY MULTI VRF - Air Source_K-Generation R2-Series Model Number: #PURY-P240TSKMU-A (-BS) The R2-Series simultaneously cools and heats different zones within a building to provide energy-saving heat-recovery operation through the use of the BC Controller. Features Supports up to 50 indoor units...


Category: air source energy recovery | air source energy recovery equipment | air-source energy recovery...

MasterFormat: Central HVAC Equipment | Packaged Outdoor HVAC Equipment | Decentralized Unitary HVAC Equipment...



Mitsubishi Electric HVAC
3400 Lawrenceville Suwanee Rd.
Suwanee, GA 30024
Tel: (800) 687-1966
Fax: (800) 658-1458

http://www.mehvac.com

Request More Info

DOWNLOADS

Related Products

Overview



CITY MULTI VRF - Air Source_K-Generation R2-Series - PURY-P240TSKMU-A (-BS)

CITY MULTI VRF - Air Source_K-Generation R2-Series


Model Number: #PURY-P240TSKMU-A (-BS)

The R2-Series simultaneously cools and heats different zones within a building to provide energy-saving heat-recovery operation through the use of the BC Controller.


Features
  • Supports up to 50 indoor units
  • Available in both 208/230V and 460V up to 30 tons for various applications
  • Cool one zone while heating another
  • Set up zones to maximize simultaneous operation
  • INVERTER-driven compressor for outstanding performance and optimized energy usage
  • Uses a two-pipe system for increased installation savings
  • Maximum pipe length: 2,624 feet


Compressor Operating Range 7% to 100%
Compressor Type x Quantity Inverter scroll hermetic compressor x 1 / Inverter scroll hermetic compressor x 1
Compressor Lubricant MEL32
Compressor Starting method Inverter
Power Source Voltage, Phase, Cycle 208 / 230V, 3 phase, 60Hz
Cooling Capacity (Nominal) 240000 Btu/h (70.3 kW) *1
Cooling Power Input (Nominal) 21.11 kW *3
Heating Capacity (Nominal) 270000 Btu/h (79.1 kW) *1
Heating Power Input (Nominal) 22.73 kW *3
Piping Diameter Liquid (High Pressure) From Twinning Kit to Indoor Units (Brazed) 1-1/8 Inches (28.58 mm) Brazed
Piping Diameter Gas (Low Pressure) From Twinning Kit to Indoor Units (Brazed) 1-3/8 Inches (34.93 mm) Brazed
Set Model With Two PURY-P120TKMU-A (-BS)
Minimum Circuit Ampacity MCA 45/42 / 45/42 Ampere *3
Maximum fuse size (time delay) MOCP 60 / 60 Ampere *3
Recommended Fuse/Breaker Size 50 / 50 Ampere *3
Refrigerant Type R410A x 26 lbs + 1 oz (11.8 kg) / R410A x 26 lbs + 1 oz (11.8 kg)
Fan Airflow Rate 11300 CFM (320 m³/min) / 11300 CFM (320 m³/min)
Fan Control, Driving mechanism Inverter-control, Brushless DC motor
Fan Type x Quantity Propeller fan x 2 / Propeller fan x 2
External Static Pressure 0.12 or 0.24"WG external static pressure;factory set to 0"WG
Sound Pressure Level (measured in anechoic room) 63 dB(A)
Indoor unit connectable Total capacity 50~150% of outdoor unit capacity
Indoor unit connectable Model (Quantity) P06~P96/2~50 (Connectable branch pipe number is max. 48.)
Operating Temperature Range Cooling (Outdoor) 23~115°F(-5~46°C) D.B. **
Operating Temperature Range Heating (Outdoor) -4~60°F(-20~15.5°C) W.B.
External Finish Pre-coated galvanized steel sheet (+powder coating for -BS type)
Protection Device High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Protection Device Inverter Circuit (Comp. / Fan) Over-current protection
Protection Device Fan Motor Thermal switch
Max. Total Refrigerant Line Length 2625 Ft. (800 m)
Max. Refrigerant Line Length (Between ODU & IDU) 541 Ft. (165 m)
Max. Control Wiring Length 1650 Ft. (503 m)
Heat Exchanger Salt-resistant cross fin & copper tube
AHRI Ratings EER (Ducted/Non-Ducted) 10.9 / 10.9
AHRI Ratings IEER (Ducted/Non-Ducted) 17.8 / 18.5
AHRI Ratings COP (Ducted/Non-Ducted) 3.38 / 3.42
AHRI Ratings SCHE (Ducted/Non-Ducted) 16.5 / 18.6