Hubbell Water Heaters -Model J Electric Booster Heater

DOWNLOADS
The Hubbell J Model is the longest lasting booster heater available because it utilizes a heavy duty ASME Section VIII designed, constructed and stamped all stainless steel tank which does not require an internal tank lining.

Category: commercial water heaters | electric water heaters | light commercial electric domestic water heaters...

MasterFormat: Plumbing Equipment | Electric Domestic Water Heaters | Light-Commercial Electric Domestic Water Heaters



Hubbell Water Heaters
45 Seymour Street
P.O. Box 288
Stratford, CT 06615
Tel: (203) 378-2659
Fax: (203) 378-3593

info@hubbellheaters.com

http://www.hubbellheaters.com/

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


Model J Electric Booster Heater

The Hubbell J Model isthe longest lasting booster heater available because it utilizes a heavy duty ASME Section VIII designed, constructed and stamped all stainless steel tank which does not require an internal tank lining. Other manufacturers use a non ASME steel tank with an internal lining that can easily erode in high temperature water and eventually leaves the bare steel tank exposed to the corrosive effects of water. Once this occurs, it is only a short time before the steel tank will begin to rust, leak and need replacement.
Hubbell did not just improve tank design - Our booster is also equipped (as standard) with the advanced functionality of an electronic temperature controller to provide accurate, reliable, and energy efficient operation while simplifying service work. The Hubbell booster's closed cell foam insulation also improves operating efficiency and reduces the cost of operation.


Heavy Duty Construction
  • All stainless steel tank construction does not require an internal lining
  • ASME Section VIII stamped construction provides for extended tank life
  • Exterior surfaces including the jacket, base and front cover are all brushed stainless steel for improved appearance and longevity
Advanced Design
  • Advanced electronic temperature control with digital display confirms at a glance proper operation and temperature setting
  • Visual indication of exact set point temperature as well as fault conditions provides instant feedback
  • Electronic leak detection system notifies user in the event of an internal water leak
  • Factory packaged resettable circuit breakers (when required) for internal over current protection save time and money compared to one shot fuses
  • A bronze body (not cast iron) pressure reducing valve is factory supplied with each booster
  • Designed for ease of service, no electrical component needs to be removed to replace any other part
  • Screw plug elements with O-ring gasket reduce leakage problems associated with less reliable and more difficult to service flange type heating elements.
Reliable
  • Overall dimensions and connections locations are compatible with other popular brands to facilitate direct replacement without modification to the existing plumbing
  • Environmentally friendly CFC/HCFC free closed cell foam insulation minimizes tank heat loss for maximum operating efficiency and reduced operating costs
  • Full ten (10) year (non pro-rated) tank warranty


Why Install A Hubbell Booster Water Heater?
  • Improved Longevity

    The Hubbell booster heater is designed to provide many years of operation. The tank is all stainless steel construction and is designed, constructed and stamped in strict conformance to ASME Section VIII.

  • Lower Operating Costs

    The Hubbell booster tank is encapsulated in environmentally friendly CFC/HCFC free closed cell foam insulation to minimize stand-by heat loss. This high quality insulation reduces heat loss compared to fiberglass type insulation found in other brands.

  • Reduced Service and Maintenance Costs

    Hubbell has greatly simplified booster heater service and maintenance through numerous advancements in booster design and controls. The Hubbell controller is a major step forward with improved ease of use and service. The digital display provides the owner and technician with an exact set point temperature as well as visual error indication. Because the controller can be set to the exact desired temperature in degrees - there is no more hotter/colder calibration. It also includes a leak detection system to notify the user in the event of an internal leak. For further ease of service and maintenance, all controls are mounted such that when a component is removed for service no other component needs to be removed, and all sensing functions have been consolidated into one probe, which can be replaced without draining the tank. The heating element and sensing probe are straight thread screw types that utilize an O-ring to minimize leakage problems as is common wit flat gaskets and NPT connections.

Plumbing Notes:
  1. Dielectric unions are recommended for installation in the inlet and outlet piping to prevent electrolysis.
  2. No check valve may be installed in the supply line to the booster.
  3. All shut off valves must be gate or ball valves - not globe valves.
  4. The brass pressure reducing valve with built-in bypass is adjustable from 25 to 75 psi.
  5. To minimize heat loss and maximize efficiency, hot water piping should be insulated.

Optional Equipment
  • Slide Brackets:
    Available for the J6 model only, these brackets allow for mounting the booster heater under a counter.
  • Shock Absorber:
    Reduce the harmful pressures resulting from quick closing dishwasher solenoid valves by installing a shock absorber between the booster and the dishwasher.
  • Tamper Resistant Package:
    For prison and other secure facilities a tamper resistant pacakge is available with all hardware tamper resistant type. Includes standard plastic legs unless otherwise specified.
  • Protective Cover:
    Keep your Hubbell booster free from dirt, debris, chemicals and execessive water with this removable form fitted protective cover. Velcro fasteners make it easily installed and simple to remove when service is required. Clear window allows visibily of Hubbell booster digital display. (J6 and J16 Boosters only)
  • Alternate Legs:
    Please specify type: Nickel plated die cast, stainless steel, stainless steel with flanged base for floor mounting
  • 24 Volt Heater Interlock Adapter:
    An optional plug adapter that interlocks the heater via a 24-Volt signal through the J1 connector on the control board (standard on the J3)
  • Water Treatment System:
    Provide superior mineral scale prevention and corrosion control by feeding a special blend of scale control compounds into the hot water stream before the booster. The in-line system to include a clear cartridge and determine when it needs a replacement without the need to open the system.
  • Alternative Voltages:
    Hubbell booster heaters are available in alternate voltages including 380, 415, 440, 575 volt
  • Low Temperature Interlock:
    This device is built into the booster and monitors water temperature and will trip an SPDT relay when water temperature drops below a set point (150 - 180°F) thereby preventing final rinse from activating
  • Remote Alarm Adapter:
    This device installs into the Hubbell controller and provides remote alarm capability to indicate a reset fault condition. Common/N.O./N.C. rated 220 VDC, 250 VAC, 2 amp max.
  • Remote Control Panel:
    This device allows you to install the booster in one location and have complete control of it (on/off, temperature adjustment, reset and temperature indication) from another location (200 feet maximum). Remote control panel is 5" x 2" x 3" and NEMA 4 rated.
Note: None of the listed optional accessories are available with J4 models.


See More


Specifications

Model Number Selection Chart with Amperage
Base Model KW
Rating
Storage Capacity Full Model Number Listed by Voltage and Phase Full Model Number Listed by Voltage and Phase Full Model Number Listed by Voltage and Phase Full Model Number Listed by Voltage and Phase Full Model Number Listed by Voltage and Phase Full Model Number Listed by Voltage and Phase Full Model Number Listed by Voltage and Phase Full Model Number Listed by Voltage and Phase Amperage Draw by Voltage and Phase Amperage Draw by Voltage and Phase Amperage Draw by Voltage and Phase Amperage Draw by Voltage and Phase Amperage Draw by Voltage and Phase Amperage Draw by Voltage and Phase Amperage Draw by Voltage and Phase
Base Model KW
Rating
Storage Capacity 120 V 208 V 208 V 240 V 240 V 480 V 480 V 600 V 120 V 208 V 208 V 240 V 240 V 480 V 600 V
Base Model KW
Rating
Storage Capacity 1 Φ 1 Φ 3 Φ 1 Φ 3 Φ 3 Φ 1 Φ 3 Φ 1 Φ 1 Φ 3 Φ 1 Φ 3 Φ 3 Φ 3 Φ
J32.93
Gallons
J32.9A-------24------
J35.73
Gallons
J35.7A-------48------
J39.93
Gallons
-J39.9RSJ39.9R------4828----
J310.43
Gallons
-J310.4RSJ310.4R------5029----
J311.43
Gallons
---J311.4SJ311.4TJ311.4T4-J311.4T6---48271411
J4 11.4 4
Gallons
- - J411R - - - - - - - 31 - - - -
J4 27 4
Gallons
- - J427R - J427T - - - - - 75 - 65 - -
J6 1 6
Gallons
J61A - - - - - - - 8 - - - - - -
J6 1.5 6
Gallons
J61.5A - - - - - - - 13 - - - - - -
J6 2 6
Gallons
J62A - - - - - - - 17 - - - - - -
J6 3 6
Gallons
J63A - - - - - - - 25 - - - - - -
J6 4 6
Gallons
- J64RS - J64S - - J64T4S - - 19 - 17 - - -
J6 5 6
Gallons
- J65RS - J65S - - J65T4S - - 24 - 21 - - -
J6 6 6
Gallons
- J66RS J66R J66S J66T J66T4 - J66T6 - 29 17 25 14 7 6
J6 7 6
Gallons
- J67RS J67R J67S J67T J67T4 - J67T6 - 34 19 29 17 8 7
J6 9 6
Gallons
- J69RS J69R J69S J69T J69T4 - J69T6 - 43 25 38 22 11 9
J6 10.5 6
Gallons
- J610RS J610R J610S J610T J610T4 - J610T6 - 50 29 44 25 13 10
J6 12 6
Gallons
- J612RS J612R J612S J612T J612T4 - J612T6 - 58 33 50 29 14 12
J6 13.5 6
Gallons
- J613RS J613R J613S J613T J613T4 - J613T6 - 65 38 56 33 16 13
J6 15 6
Gallons
- J615RS J615R J615S J615T J615T4 - J615T6 - 72 42 63 36 18 14
J6 18 6
Gallons
- J618RS J618R J618S J618T J618T4 - J618T6 - 87 50 75 43 22 17
J6 24 6
Gallons
- J624RS J624R J624S J624T J624T4 - J624T6 - 115 67 100 58 29 23
J6 27 6
Gallons
- J627RS J627R J627S J627T J627T4 - J627T6 - 130 75 113 65 33 26
J6 30 6
Gallons
- J630RS J630R J630S J630T J630T4 - J630T6 - 144 83 125 72 36 29
J6 36 6
Gallons
- J636RS J636R J636S J636T J636T4 - J636T6 - 173 100 150 87 43 35
J6 39 6
Gallons
- J639RS J639R J639S J639T J639T4 - J639T6 - 188 108 163 94 47 38
J6 40.5 6
Gallons
- J640RS J640R J640S J640T J640T4 - J640T6 - 195 113 169 98 49 39
J6 45 6
Gallons
- - J645R J645S J645T J645T4 - J645T6 - - 125 188 108 54 43
J6 54 6
Gallons
- - J654R - J654T J654T4 - J654T6 - - 150 - 130 65 52
J6 58.5 6
Gallons
- - J658R - J658T J658T4 - J658T6 - - 163 - 141 70 56
J16 1 16
Gallons
J161A - - - - - - - 8 - - - - - -
J16 1.5 16
Gallons
J161.5A - - - - - - - 13 - - - - - -
J16 2 16
Gallons
J162A - - - - - - - 17 - - - - - -
J16 3 16
Gallons
J163A - - - - - - - 25 - - - - - -
J16 4 16
Gallons
- J164RS - J164S - - J164T4S - - 19 - 17 - - -
J16 5 16
Gallons
- J165RS - J165S - - J165T4S - - 24 - 21 - - -
J16 6 16
Gallons
- J166RS J166R J166S J166T J166T4 - J166T6 - 29 17 25 14 7 6
J16 7 16
Gallons
- J167RS J167R J167S J167T J167T4 - J167T6 - 34 19 29 17 8 7
J16 9 16
Gallons
- J169RS J169R J169S J169T J169T4 - J169T6 - 43 25 38 22 11 9
J16 10.5 16
Gallons
- J1610RS J1610RJ1610SJ1610TJ1610T4 - J1610T6 - 50 29 44 25 13 10
J16 12 16
Gallons
- J1612RSJ1612RJ1612SJ1612TJ1612T4 - J1612T6 - 58 33 50 29 14 12
J16 13.5 16
Gallons
- J1613RSJ1613RJ1613SJ1613TJ1613T4 - J1613T6 - 65 38 56 33 16 13
J16 15 16
Gallons
- J1615RSJ1615RJ1615SJ1615TJ1615T4 - J1615T6 - 72 42 63 36 18 14
J16 18 16
Gallons
- J1618RSJ1618RJ1618SJ1618TJ1618T4 - J1618T6 - 87 50 75 43 22 17
J16 24 16
Gallons
- J1624RSJ1624RJ1624SJ1624TJ1624T4 - J1624T6 - 115 67 100 58 29 23
J16 27 16
Gallons
- J1627RSJ1627RJ1627SJ1627TJ1627T4 - J1627T6 - 130 75 113 65 33 26
J16 30 16
Gallons
- J1630RSJ1630RJ1630SJ1630TJ1630T4 - J1630T6 - 144 83 125 72 36 29
J16 36 16
Gallons
- J1636RSJ1636RJ1636SJ1636TJ1636T4 - J1636T6 - 173 100 150 87 43 35
J16 39 16
Gallons
- J1639RSJ1639RJ1639SJ1639TJ1639T4 - J1639T6 - 188 108 163 94 47 38
J16 40.5 16
Gallons
- J1640RSJ1640RJ1640SJ1640TJ1640T4 - J1640T6 - 195 113 169 98 49 39
J16 45 16
Gallons
- - J1645RJ1645SJ1645TJ1645T4 - J1645T6 - - 125 188 108 54 43
J16 54 16
Gallons
- - J1654R - J1654TJ1654T4 - J1654T6 - - 150 - 130 65 52
J16 58.5 16
Gallons
- - J1658R - J1658TJ1658T4 - J1658T6 - - 163 - 141 70 56
J16 with 1-1/2" inlet outlet6416
Gallons
--J1664R-------178----
J16 with 1-1/2" inlet outlet6816
Gallons
----J1668TJ1668T4-J1666T6----1648266
J16 with 1-1/2" inlet outlet8116
Gallons
--J1681R-J1681TJ1681T4----225-19598-
J16 with 1-1/2" inlet outlet8616
Gallons
--J1686R----J1685T6--239---83
J16 with 1-1/2" inlet outlet8816
Gallons
----J1688TJ1688T4------212106-
Model J6 (1-18 kW) Dimensions
Model J6 (24-58.5 kW) Dimensions
Model J16 (1-58.5 kW) Dimensions
Model J16 (64-88 kW) Dimensions
Model J3 (2.9-11.4 kW) Dimensions
Model J4 (11.4-27 kW) Dimensions
Recovery Ratings 1-58.5 kW Recovery Ratings 1-58.5 kW Recovery Ratings 1-58.5 kW Recovery Ratings 1-58.5 kW Recovery Ratings 1-58.5 kW Recovery Ratings 1-58.5 kW Recovery Ratings 1-58.5 kW Recovery Ratings 1-58.5 kW Recovery Ratings 1-58.5 kW
KW Rating Recovery Rate in GPH at °F Temperature Rise (ΔT) Recovery Rate in GPH at °F Temperature Rise (ΔT) Recovery Rate in GPH at °F Temperature Rise (ΔT) Recovery Rate in GPH at °F Temperature Rise (ΔT) Recovery Rate in GPH at °F Temperature Rise (ΔT) Recovery Rate in GPH at °F Temperature Rise (ΔT) Recovery Rate in GPH at °F Temperature Rise (ΔT) Recovery Rate in GPH at °F Temperature Rise (ΔT)
KW Rating 20° ΔT 30° ΔT 40° ΔT 60° ΔT 70° ΔT 80° ΔT 110° ΔT 140° ΔT
120141076543
1.5312015109864
241272014121076
361413120 1815119
48255412723201512
510268513429261915
612382614135312218
714396724841362620
9184123926153463326
10.52151431077261543931
122461641238270614535
13.52761841389279695039
1530720515410288775644
18368246184123105926753
244913282461641401238970
2755336827618415813810079
3061440930720517515411288
36737491368246211184134105
39798532399266228200145114
40.5829553415276237207151118
45921614461307263230167132
541105737553368316276201158
58.51198798599399342299218171
Recovery Ratings 64-88 kW Recovery Ratings 64-88 kW Recovery Ratings 64-88 kW Recovery Ratings 64-88 kW Recovery Ratings 64-88 kW Recovery Ratings 64-88 kW Recovery Ratings 64-88 kW Recovery Ratings 64-88 kW Recovery Ratings 64-88 kW
641310873655437374328238187
681392928696464398348253199
8116581105829553474415301237
8617611174880587503440320252
8818021201901601515450328257
Voltage De-Rating Factors
Rated VoltageApplied VoltageDe-Rating Factor
600 V575 V92%
600 V550 V84%
480 V460 V92%
480 V440 V84%
240 V230 V92%
240 V220 V84%
240 V208 V75%
Sweetsstakes