Hubbell Water Heaters - Model BW ASME Packaged Indirect Fired Water Heater

DOWNLOADS
The Model BW is a fully packaged indirect fired water heater which utilizes boiler water or high temperature hot water (HTHW) as the energy source for heating potable water. The entire package is designed to be a reliable and long lasting source for hot water.

Category: industrial water heaters | process heaters | process water heaters...

MasterFormat: Plumbing Equipment | Domestic Water Heat Exchangers



Hubbell Water Heaters
45 Seymour Street
P.O. Box 288
Stratford, CT 06615
Tel: (203) 378-2659
Fax: (203) 378-3593

info@hubbellheaters.com

http://www.hubbellheaters.com/

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

Overview


Model BW ASME Packaged Indirect Fired Water Heater

The Model BW is a fully packaged indirect fired water heater which utilizes boiler water or high temperature hot water (HTHW) as the energy source for heating potable water. The entire package is designed to be a reliable and long lasting source for hot water. Each component is carefully selected to ensure high performance in even the most demanding application. Whether you are heating potable water in a commercial building or process water in an industrial application, you can select a Hubbell BW model to do the job. When you specify and install a Hubbell indirect water heater, you will be provided with a quality product that is a long lasting and trouble-free source for hot water.


Reliable
  • Only high grade materials used in construction to ensure long operating life
  • Hydrastone cement lining provides superior protection and tank longevity
  • Heavy duty construction withstands demanding commercial/industrial use
Packaged System
  • Factory selected and sized boiler water control valve simplifies installation and ensures reliable operation
Versatile
  • Full range of styles, sizes, and optional features to meet your exact heating needs

Boiler Water Control Valve Selection

Hubbell Model BW indirect fired water heaters are factory furnished with a boiler water control system to regulate the flow of boiler water through the heating coil. The following is an overview of the various Boiler Water Control Systems available.

This is the most commonly selected method for regulating the boiler water. A 3-Way control valve allows only the required amount of boiler water into the heating coil in order to satisfy the demand. Any excess boiler water is diverted back to the boiler water circulating loop. This valve type can be selected as either electric or pneumatic powered.

This control system will allow only the required amount of boiler water into the coil to satisfy the demand. As the water temperature in the tank approaches the set point, the flow of boiler water to the coil is decreased. This control valve does not divert unused boiler water back to the circulation loop. This valve can be selected as either electric or pneumatic powered. For proper valve sizing, the boiler water pressure must be know to ensure that the valve can properly close off during operation.

This control system operates via a thermostat which opens or closes the control circuit to an independent boiler water circulation pump. The thermostat is wired into the control circuit of the circulation pump and will close the control circuit when heat is required (thereby turning the pump on) and will open the control circuit when the water temperature in the storage vessel reaches the thermostat set point, thereby turning the pump off.


Model BW Storage Type Standard Equipment
Vessel Construction
  • All welded carbon steel pressure vessel designed and built in strict accordance with the ASME Code Section VIII and stamped, certified, and registered with the National Board of Boiler and Pressure Vessel Inspectors
  • All internal tank surfaces are lined with a minimum of 5/8" thick Hydrastone cement for superior protection and tank longevity
  • Designed for 125 psi working pressure and hydrostatically tested
Heating Coil
  • Factory sized and installed heating coil with a generously sized heating surface designed to ensure reliable operation
  • U-Tube heating coil constructed from single wall copper tubing designed for a maximum working pressure of 150 psi
  • Heavy duty fabricated steel head with with threaded NPT inlet and outlet connections
  • All wetted parts are non-ferrous for maximum longevity
  • Non-Ferrous tube sheet
  • Reference Heating Coils for detailed heating coil construction features
Boiler Water Operating Controls
  • Operating controls are factory selected, sized, piped and tested to ensure reliable operation
  • All components are factory piped and ready for boiler water in and out connections
  • Modulating control valve (2-way or 3-way) to regulate the flow of boiler water through the coil. Modulating control valve to be either electric or pneumatic powered
General
  • Heavy duty 3" thick fiberglass insulation for maximum operating efficiency and minimal stand-by heat loss
  • Heavy gauge painted galvanized steel protective outer jacket
  • Heavy duty integrally welded steel supports for floor mounting
  • Full five (5) year Non Pro-Rated tank warranty and a one (1) year component warranty
  • ASME rated combination T&P relief valve set at the tank working pressure and 210°F

Model BW Optional Equipment
Vessel
  • Alternate protective lining: Phenolic epoxy resin, Flame spray copper, Hot dip galvanizing, other
  • Alternate vessel construction: Stainless Steel Type 304 or 316L, 90/10 Copper-Nickel, other
  • Alternate working pressure: specify
  • Horizontal Construction: (BWH)
Heating Coil
  • Double wall tubing with a leak detection port
  • Alternate tubing material (Stainless Steel, 90/10 Copper-Nickel, Admiralty)
  • Fabricated head constructed from (Stainless Steel, Copper Alloy)
General
  • Skid mounting on heavy duty all welded I beam
  • Type 304 stainless steel protective outer jacket
Operating Controls
  • Boiler water control valve can be factory selected and sized, but shipped loose for in the field installation by others
  • Single solenoid safety system closes the boiler water supply to the heating coil should the water temperature in the tank reach the hi-limit set point. Requires 120 volt 5 amp electrical service
  • A double solenoid safety system dumps over heated water in the storage tank to drain in addition to closing the boiler water supply to the heating coil. Requires 120 volt 5 amp electrical service. Note: Not recommended for storage tank applications greater than 200 gallons.
  • Intra-tank circulation pump package continuously circulates water within the tank in order to reduce stratification
  • Dial water thermometer and pressure gauge factory installed in the tank
  • Anticipator control system forces incoming cold water over the control valve sensing bulb in order to begin heating water immediately
  • Factory wrapped and baffled heating coil with integral pump package
  • Dual energy package provides operational flexibility by utilizing an electric back-up heating element.


See More


Specifications

Model BW (Vertical)
Model BWH (Horizontal)
Actual Storage Capacity (Gallons) Overall Dimensions (Inches) Overall Dimensions (Inches) Overall Dimensions (Inches) Overall Dimensions (Inches) Overall Dimensions (Inches) Storage Tank Nominal Storage Capacity (Gallons) Inlet Outlet Sizing (NPT) Approx. Shipping Weight (Lbs.)
Actual Storage Capacity (Gallons) Vertical Vertical Horizontal Horizontal Horizontal Storage Tank Nominal Storage Capacity (Gallons) Inlet Outlet Sizing (NPT) Approx. Shipping Weight (Lbs.)
Actual Storage Capacity (Gallons) Diameter "A" Height "B" Length "C" Width "D" Height "E" Diameter x Length Nominal Storage Capacity (Gallons) Inlet Outlet Sizing (NPT) Approx. Shipping Weight (Lbs.)
80* 26 65 60 26 32 22 x 54 90 1.5 700
120* 28 75 68 28 34 24 x 64 140 1.5 900
150* 30 79 72 30 36 26 x 68 170 1.5 1100
175 36 73 67 36 44 30 x 63 195 1.5 1500
200 36 82 76 36 44 30 x 72 220 1.5 1700
225 36 89 83 36 44 30 x 79 245 1.5 1750
250 42 74 68 42 50 36 x 64 285 1.5 1850
275 42 80 74 42 50 36 x 70 310 1.5 2000
300 42 88 82 42 50 36 x 78 345 1.5 2180
325 42 92 86 42 50 36 x 82 360 1.5 2300
350 42 94 88 42 50 36 x 84 370 1.5 2500
375 48 81 75 48 56 42 x 71 425 1.5 2600
400 48 85 79 48 56 42 x 75 450 1.5 2700
425 48 88 82 48 56 42 x 78 470 1.5 2900
450 48 93 87 48 56 42 x 83 500 1.5 3000
475 54 79 73 54 62 48 x 69 540 2 3100
500 54 82 76 54 62 48 x 72 565 2 3225
525 54 85 79 54 62 48 x 75 590 2 3350
550 54 89 83 54 62 48 x 79 620 2 3400
575 54 93 87 54 62 48 x 83 650 2 3500
600 54 95 89 54 62 48 x 85 665 2 3650
700 54 107 101 54 62 48 x 97 755 2 4000
800 54 119 113 54 62 48 x 109 850 2 4300
900 54 132 126 54 62 48 x 122 940 2 4800
1000 54 145 139 54 62 48 x 135 1060 2 5200
1250 60 149 143 60 68 54 x 139 1380 2 5600
1500 60 174 168 60 68 54 x 164 1625 2 6000
1750 66 168 162 66 74 60 x 158 1935 3 7400
2000 66 185 179 66 74 60 x 175 2145 3 8100
2500 78 169 163 78 86 72 x 159 2800 3 8200
3000 78 197 191 78 86 72 x 187 3300 3 8300
3500 90 174 168 90 98 84 x 164 3935 6 FLG. 8900
4000 90 195 189 90 98 84 x 185 4440 6 FLG. 9800
4500 N/A N/A 168 102 108 96 x 160 5015 6 FLG. 10700
5000 N/A N/A 183 102 108 96 x 175 5485 6 FLG. 11600
Note: All dimensions are approximate and subject to change. Please reference the submittal drawing for actual dimensions. The tank selections above are shown for convenience.
*80, 120, and 150 gallon tanks do not come equipped with a manway.
Note: All dimensions are approximate and subject to change. Please reference the submittal drawing for actual dimensions. The tank selections above are shown for convenience.
*80, 120, and 150 gallon tanks do not come equipped with a manway.
Note: All dimensions are approximate and subject to change. Please reference the submittal drawing for actual dimensions. The tank selections above are shown for convenience.
*80, 120, and 150 gallon tanks do not come equipped with a manway.
Note: All dimensions are approximate and subject to change. Please reference the submittal drawing for actual dimensions. The tank selections above are shown for convenience.
*80, 120, and 150 gallon tanks do not come equipped with a manway.
Note: All dimensions are approximate and subject to change. Please reference the submittal drawing for actual dimensions. The tank selections above are shown for convenience.
*80, 120, and 150 gallon tanks do not come equipped with a manway.
Note: All dimensions are approximate and subject to change. Please reference the submittal drawing for actual dimensions. The tank selections above are shown for convenience.
*80, 120, and 150 gallon tanks do not come equipped with a manway.
Note: All dimensions are approximate and subject to change. Please reference the submittal drawing for actual dimensions. The tank selections above are shown for convenience.
*80, 120, and 150 gallon tanks do not come equipped with a manway.
Note: All dimensions are approximate and subject to change. Please reference the submittal drawing for actual dimensions. The tank selections above are shown for convenience.
*80, 120, and 150 gallon tanks do not come equipped with a manway.
Note: All dimensions are approximate and subject to change. Please reference the submittal drawing for actual dimensions. The tank selections above are shown for convenience.
*80, 120, and 150 gallon tanks do not come equipped with a manway.
Note: All dimensions are approximate and subject to change. Please reference the submittal drawing for actual dimensions. The tank selections above are shown for convenience.
*80, 120, and 150 gallon tanks do not come equipped with a manway.