![]() Chemical Products Industries, Inc. 7649 SW 34th Street Oklahoma City, OK 73179 Phone: (405) 745-2070 Toll Free: (800) 624-4356 Fax: (405) 745-2276 Email: jordan@cpiinc.net Website: http://www.chemicalproductsokc.com ![]() Technical Data Sheet CP-500W™Water Repellent Product Data and Test Information PRODUCT NAME
PRODUCT DESCRIPTION CP-500W™ reacts with the silica in concrete and masonry in the presence of ultraviolet light and atmospheric moisture. This reaction forms strong permanent bonds beneath the surface and creates a hydrophobic zone that prevents water molecules from penetrating, while allowing free migration of water vapors. The chemical bonds formed in this process allow CP-500W™ to become integral part of the substrate and provide long-term water repellent protection. APPLICATIONS Protects horizontal surfaces such as pavements, sidewalks and plazas. It should also be used on vertical surfaces with leaks and or where extra protection is desired. Also protects bridges, parking decks, airport taxiways and aprons, piers and marine structures, and other surfaces requiring outstanding corrosion resistance and protection from chloride penetration. For use on brick masonry to protect against the entrance of wind-driven rain. To reduce the effects of mildew, efflorescence, and stains from concrete and masonry. ADVANTAGES Benefits of this product are:
Chemical Products' state-of-the-art protective treatments have developed a reputation by architects and building professionals as the premier solution for water repellents and sealers. Chemical Products' is dedicated to solving the destructive influence water intrusion and other elements have on building materials. APPEARANCE PRETREATMENT FOR PAINT TECHNICAL DATA TEST DATA ASTM C 140 % Reduction in Water Absorption on 3000 psi Concrete During Immersion
in Water for 24 hrs. ASTM C 97 % Reduction in Water Absorption on Indiana Limestone During Immersion
in Water for 48 hrs. ASTM C672 “Deicer Scaling” ASTM E 514 “Water Permeance of Masonry” ASTM D 1653 Water Vapor Transmission LIMITATIONS Application should be completed by qualified applicator with experience applying water repellents. Application equipment should be clean and free of foreign materials which could be dissolved and deposited on surfaces to be treated. Contact CPI for additional precautions and information on compatibility with specific materials. INSTALLATION As a standard procedure, fresh concrete should be allowed to dry for 28 days before application. All repointing must be completed and allowed to cure at least 3 days. Concrete repair and replacement must be completed prior to application. Patching materials, caulking, sealing materials, traffic paint must be fully cured before applying CP-500W™. In addition, the actual amount of material that is used for each application is dependent on the absorptive capacity of the substrate. Before applying, it is recommended that preliminary tests be carried out to determine usage and to test the effectiveness of the treatment. Application: Apply water repellents as early as practical to protect substrates during construction, but not before wall cap, flashings, and roof are in place and water trapped in structure has been drained. Spray apply CP-500W™ by low-pressure (150 psi maximum) pumping equipment with a wet fan type spray nozzle. Alternate methods include nap roller (1”) or by brush. Required application rate varies from 70 to 175 sq. ft. per gallon depending on surface texture and absorbency. Vertical Surfaces: Mix well before using. Test small area before starting general application to assure desired results and coverage rates. Apply when surface and air temperatures are between 40° F to 110° F. Provide adequate ventilation. Apply in a flooding application, from the bottom up so the material runs down 6 to 8 inches below the spray pattern. On horizontal surfaces the liquid material should pond on the surface at least 5 seconds before being absorbed. For best results two applications are recommended with the second application applied using a wet on wet technique, retreat within three to five minutes after initial application. A wet treated surface may be agitated with a soft bristle scrub brush to ensure more even distribution and greater penetration. During application, precautions should be taken to protect the surrounding area from overspray. Remove overspray from non-targeted surfaces immediately with soap and water. Apply to southern exposed areas during coolest part of the day. Horizontal Surfaces: Mix well before using. Pretest to measure material coverage rates. Apply enough material so that solution stands for 60 seconds before completely penetrating the surface. If additional material is required to reach desired coverage rate, a wet on wet application can be used. Avoid puddling or ponding, brush or broom to spread material to more porous area. If applicable, block all drains and use absorptive coverings to contain run-off of excess material. To avoid unnecessary clean-up, use soap and water to remove overspray as soon as possible. Caution: Over application of material may cause darkening of surface. Dry Time: To touch, or 2 to 6 hours depending on temperature and humidity. WARRANTY AVAILABILITY TECHNICAL SERVICE |