Thermafiber SAFBs (Sound Attenuation Fire Blankets) are mineral wool batts designed to stop sound, saving energy, and providing life saving fire protection. SAFBs are available with up to 90% post-industrial recycled content. These products are noncombustible, moisture-resistant, noncorrosive, nondeteriorating, mildew-proof and vermin-proof. Thermafiber SAFBs provide acoustical control, thermal insulation, and fire protection in many different UL fire rated wall and floor-ceiling assemblies. SAFBs resist temperatures over 2000°F as compared to fiberglass insulation that melts around 1000°F. SAFBs add STCs to wall and floor-ceiling assemblies. See Thermafiber's SAFB Brochure (TF885) for more detail on STC and fire ratings for multiple wall and floor-ceiling assemblies.
Depending on the particular assembly and application, partition STC ratings have been improved up to nine points by installing Thermafiber SAFBs in the stud cavity. The insulation also has been shown to improve MTC ratings for low-frequency sound attenuation, isolating sounds from machinery, mechanical equipment and music. SAFBs are superior to glass fiber in sound attenuation. In fact, low-density glass fiber insulation must be nearly twice as thick as standard Thermafiber SAFB to provide the same attenuation.
- Standard Fiber SAFB = 70% Post-Industrial Recycled Content
- EPA Choice Fiber SAFB (For US Government Projects) = 75% Post-Industrial Recycled Content
- Meets the EPA Comprehensive Procurement Guidelines for Rock Wool insulation
- Green Fiber SAFB = 90% Post-Industrial Recycled Content
- Creased SAFB - Made 1" wider than standard stud spacing to bow in the stud cavity for increased sound absorption.
- Interior Stud Cavity - Friction fit SAFBs securely between studs. Butt ends of blankets closely together and fill all voids.
- Creased SAFB - Bow the blankets slightly to fit into stud cavity. Slit the blankets vertically 1" deep with a utility knife.
- Floor-Ceiling - Friction fit SAFBs securely between floor joists.
- Ceiling Overlayment - Lay SAFBs over ceiling panels extending 48" beyond all partitions. Tightly fit around all hangers, obstructions, and penetrations.
| Thickness* | Widths | Lengths | SAFB 2.5 pcf | 1 - 1/2" - 6" | 16", 17", 24", 25" | 48" | SAFB 4.0 pcf | 1" | 16", 17", 24", 25" | 48" | Tolerances | ±1/4" - 1/8" | ±1/8" | ±1/2" | *Thicknesses are available in 1/2" increments. Custom sizes (width and length) are available upon request. |
Tested to ASTM E 84 | | | Tested to ASTM C 518 | Unfaced | Product
Designation | Actual
Density | "K" @ 75° [24°C]
BTU.in/hr.sq. ft. °F | "R" value per
inch of thickness** | Flame Spread | Smoke Developed | SAFB | 2.5 pcf | 0.27 | 3.7 | 0 | 0 | SAFB | 4.0 pcf | 0.24 | 4.2 | 0 | 0 | **R= thickness divided by 'k' |
| Coefficeints at Frequencies Per ASTM 423 | Thickness | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz | NRC | SAFB 2.5 pcf
Density | 2" | 0.34 | 0.61 | 1.07 | 1.09 | 1.07 | 1.10 | 0.95 | 3" | 0.51 | 0.99 | 1.18 | 1.03 | 0.99 | 0.96 | 1.05 | 4" | 0.83 | 1.19 | 1.27 | 1.12 | 1.12 | 1.13 | 1.20 | 6" | 1.37 | 1.32 | 1.23 | 1.16 | 1.12 | 1.12 | 1.20 |
Thermafiber offers industry leading technical and engineering assistance to architects, specifiers, and contractors. These services include CAD drawings, engineering judgments, LEED Credit Information, and product recommendations. Contact our technical services department at 1-888-834-2371, or email technicalservices@thermafiber.com. STANDARDS COMPLIANCE
Thermafiber Sound Attenuation Fire Blankets meet the following: NFPA 101 Class A rated interior finish ASTM C 665 Type I, per Federal Specification HH-I-521F ASTM E 136 Rated Non-combustible per NFPA Standard 220 ASTM C 1104 Absorbs less than 1% by volume SAFB products are approved by: New York City Board of Standards & Appeals - (under BSA 35-66-SM, 173-77-M, 249-74-SM, 34-66-SM, & accepted by MEA 207-82-M, Vol. 2) Thermafiber, Inc.