Metal Roofing Englert Series 1300

Englert, Inc.
1200 Amboy Avenue
P.O. Box 149
Perth Amboy, NJ 08861
Tel: (732) 826-8614
Fax: (732) 826-8865
Email: englert.inc@prodigy.net
Web site: http://www.englertinc.net

PRODUCT PRESENTATION

Englert Series 1300 1" and 1-1/2" high seams are variable width (12" - 24") roof panel profiles rollformed with optional stiffening ribs. The panels are secured by fixed or floating clips, allowing for unrestricted thermal movement. The panels are seamed either 90° or 180° by electric seamers. All fasteners are concealed.

Clip spacing is 24" o.c. for panels up to 16" wide and 16" - 18" o.c. for panel widths 18" - 24" o.c. with 2 fasteners per clip. Fixed clips are recommended on panel lengths under 40’. Use floating clips on panels over 40’.

As an integrated roofing system, Series 1300, 1" and 1-1/2" profiles must be installed over solid deck (at least 1/2" thick plywood or 22 gauge metal deck), with an underlayment of two layers of 15# felt. For other conditions, check with the manufacturer. Minimum slope is 3"/12". Do not install panels directly over chemically treated plywood.

SPECIFICATIONS

A. Panel system shall be the Englert Series 1300, 1" or 1-1/2" high, 16" or 20" wide panel, Standing Seam System, (with pencil ribs and 2 mechanically seamed styles, optional), with sealant applied at the panel interlock, specify "with battens" if you wish a batten appearance. The panels shall have baked on finish as specified in Section 2.05 hereunder, in manufacturer’s standard colors. The manufacturer shall offer at least a minimum of 23 standard colors to choose from.

B. Substrate

- 24 gauge baked on finish over Galvalume ASTM A-792-83, AZ55, 40 KSI yield point, 52 KSI tensile strength.
- *22 gauge baked on finish over Galvalume per ASTM A-792-83, AZ55, 40 KSI yield point, 52 KSI tensile strength.
- *.032" or .040" aluminum alloy 3105-H14 approved equal.
NOTE TO SPECIFIER: *22 gauge steel, and .032" and .040" aluminum are available subject to minimum order requirements. Call Englert for details.

C. Performance

1. ASTM E-283-84 air infiltration: Maximum of 0.003 CFM./Ft2 at 10 psf pressure differential on 180° seamed profile and 0.006 CFM./Ft2 at 20 psf pressure differential.
2. ASTM E-331-84 water penetration: No evidence of uncontrolled leakage on 180° seamed panel at 20 psf pressure differential.
3. Panel shall display a flame spread classification of a Class 1 when tested in accordance with ASTM E-84-87.
4. The Series 1300 has been proven, through engineering analysis, to meet the criteria and loading of the standard UL-90 uplift test, at 16" wide in 24 gauge steel over a solid substrate using special clips. Report available upon request. (This system is not UL-90 rated).
5. Panel shall be tested and conform to the requirements of the Dade County Florida non-structural roofing system criteria, product approval number must be supplied for records.

Englert, Inc.
1200 Amboy Avenue
P.O. Box 149
Perth Amboy, NJ 08861
Tel: (732) 826-8614
Fax: (732) 826-8865
Email: englert.inc@prodigy.net
Web site: http://www.englertinc.net

Englert, Inc.

Colorado
Phone: (303) 288-8070

Connecticut
Phone: (203) 265-6704

Florida
Phone: (813) 248-2296

Massachusetts
Phone: (508) 774-0006

New Jersey
Phone: (732) 826-8610

Pennsylvania
Phone: (412) 461-1355

Tennessee
Phone: (423) 970-0090

Virginia
Phone: (703) 922-9666
(757) 363-0622