PRODUCT PRESENTATION
Englert Series 1300 1" and 1-1/2" high seams are variable
width (12" - 24") roof panel profiles rollformed with optional
stiffening ribs. The panels are secured by fixed or floating clips,
allowing for unrestricted thermal movement. The panels are seamed either
90° or 180° by electric seamers. All fasteners are concealed.
Clip spacing is 24" o.c. for panels up to 16" wide and 16"
- 18" o.c. for panel widths 18" - 24" o.c. with 2 fasteners
per clip. Fixed clips are recommended on panel lengths under 40. Use
floating clips on panels over 40.
As an integrated roofing system, Series 1300, 1" and 1-1/2"
profiles must be installed over solid deck (at least 1/2" thick
plywood or 22 gauge metal deck), with an underlayment of two layers of 15#
felt. For other conditions, check with the manufacturer. Minimum slope is
3"/12". Do not install panels directly over chemically treated
plywood.
SPECIFICATIONS
A. Panel system shall be the Englert Series 1300, 1" or 1-1/2"
high, 16" or 20" wide panel, Standing Seam System, (with pencil
ribs and 2 mechanically seamed styles, optional), with sealant applied at
the panel interlock, specify "with battens" if you wish a batten
appearance. The panels shall have baked on finish as specified in Section
2.05 hereunder, in manufacturers standard colors. The manufacturer
shall offer at least a minimum of 23 standard colors to choose from.
B. Substrate
- 24 gauge baked on finish over Galvalume ASTM A-792-83, AZ55, 40 KSI
yield point, 52 KSI tensile strength.
- *22 gauge baked on finish over Galvalume per ASTM A-792-83, AZ55, 40
KSI yield point, 52 KSI tensile strength.
- *.032" or .040" aluminum alloy 3105-H14 approved equal.
NOTE TO SPECIFIER: *22 gauge steel, and .032" and
.040" aluminum are available subject to minimum order requirements.
Call Englert for details.
C. Performance
1. ASTM E-283-84 air infiltration: Maximum of 0.003 CFM./Ft2 at 10
psf pressure differential on 180° seamed profile and 0.006 CFM./Ft2
at 20 psf pressure differential.
2. ASTM E-331-84 water penetration: No evidence of uncontrolled leakage
on 180° seamed panel at 20 psf pressure differential.
3. Panel shall display a flame spread classification of a Class 1 when
tested in accordance with ASTM E-84-87.
4. The Series 1300 has been proven, through engineering analysis, to meet
the criteria and loading of the standard UL-90 uplift test, at 16"
wide in 24 gauge steel over a solid substrate using special clips. Report
available upon request. (This system is not UL-90 rated).
5. Panel shall be tested and conform to the requirements of the Dade
County Florida non-structural roofing system criteria, product approval
number must be supplied for records.
Englert, Inc.
1200 Amboy Avenue
P.O. Box 149
Perth Amboy, NJ 08861
Tel: (732) 826-8614
Fax: (732) 826-8865
Email: englert.inc@prodigy.net
Web site: http://www.englertinc.net
Englert, Inc.
Colorado
Phone: (303) 288-8070
Connecticut
Phone: (203) 265-6704
Florida
Phone: (813) 248-2296
Massachusetts
Phone: (508) 774-0006
New Jersey
Phone: (732) 826-8610
Pennsylvania
Phone: (412) 461-1355
Tennessee
Phone: (423) 970-0090
Virginia
Phone: (703) 922-9666
(757) 363-0622