ThermaCalX®
Nailable Extruded Polystyrene Roof Insulation
 
ThermaCalX is a nail base roof insulation which combines oriented strand board and extruded polystyrene foam. The standard nail base is APA performance rated 7/16" O.S.B.  Also available are 5/8" and ¾” O.S.B. or plywood.  The sheathing is pre-spaced for thermal expansion. Tongue and groove edges greatly reduce heat loss at joints.  The insulation has a very low moisture absorption rate and excellent R value retention.

Please see the attached Data Table for available sizes and performance data.

USES, APPLICATIONS
ThermaCalX insulation is designed for use with shingle or metal roofing, slate and tile.

UNDERWRITERS LABORATORIES
ThermaCalX  foam complies with ASTM C578 and UL Roof Deck Construction #457 for use directly over metal deck.

CODES AND COMPLIANCES

CODE ACCEPTABILITY CERTIFICATION
Codes – O.S.B. is approved by CABO, ICBO, BOCA, SBC, ARMA and the APA as roof sheathing. The foam used in ThermaCalX has a Flame Spread Rating of 5. (This numeric Flame Spread Rating is not intended to reflect hazards presented by this or any other material under actual fire conditions).

Plastic foam must be protected from flame on the inside by a suitable barrier.  Generally, wood decking or drywall is acceptable and plywood or metal decking are allowed in certain roofing applications. CHECK LOCAL CODES.

FEDERAL SPECIFICATION – foam meets HUD/FHA Use of Materials Bulletin No. UM71a, ASTM C578 and AASHTO M230.

MODEL CODES - foam insulation is in compliance with:
BOCA - Section 2603.0
ICBO - Section 2602
SBCCI - Section 2603.2

DRAFT SPECIFICATION-SHORT FORM
Note to Specification Writer: This spec is usually placed in Section 07220 (07 22 00). It can be downloaded from our website www.cornellcorporation.com.

SPECIFICATIONS
Note to Specification Writer: Please see attached 3-part specification. This spec is usually placed in Section 07220 (07 22 00). Or, it can be downloaded from our website www.cornellcorporation.com.

TECHNICAL
Vapor retarders – The designer should determine if a vapor retarder is required between the deck and the insulation.  A vapor retarder should always be specified in buildings with high humidity conditions, such as swimming pools.

GENERAL
Catalogs, detail drawings, draft specifications and installation instructions are available. Call 888-439-6411 or FAX 800-267-8368.
 
OTHER PRODUCTS
Please see the attached table for a quick selection guide to Cornell’s roof sheathing and insulation products.

MANUFACTURER
Cornell Corporation has been a leading roof insulation manufacturer since 1954.  In response to the need for nailable insulation above the structural roof deck in cathedral or vaulted ceiling applications, Cornel Corporation introduced ThermaCal® in 1979, which started the nail base roof insulation industry. In response to the shingle manufacturers’ requests for ventilation, we introduced Vent-Top ThermaCal in 1987.  Cornell Corporation – your ventilated roof insulation specialists!


CORNELL CORPORATION
808 South 3rd Street
P.O. Box 338
Cornell , Wisconsin 54732
Tel: (888) 439-6411
Fax: (800) 267-8368
E-Mail: cornell@cornellcorporation.com