Owens Corning World Headquarters
One Owens Corning Parkway
Toledo, OH 43659
Toll-Free: (800) GET-PINK
Web site: http://www.owenscorning.com
 

QuietZone Acoustic Wall Framing

Designed to replace conventional wall framing in noise control applications, QuietZone Acoustic Wall Framing combines two sections of Trus JoistTimberStrand® LSL connected by several acoustically resilient metal clips. This framing allows walls to be built with better STC ratings, while maintaining nominal wall depths. Therefore, walls can be installed at a lower cost than alternative construction techniques such as resilient channels or staggered studs.
 
Product Specifications - Maximum Vertical Load (plf) Interior Walls Only
Wall
Height
Member
Length
2 x 4 Wall
On-Center Spacing
2 x 6 Wall
On-Center Spacing
  12" 16" 24" 12" 16" 24"
8' 92-5/8" 1204 837 479 2365 1774 1183
9' 104-5/8"  892 607 331 2365 1774 1183
10' 116-5/8"  671 446 227 2365 1774 1183
12' 144"       1742 1203 680
14' 168"       1179 791 414

Fire Safety and Applicable Standards

QuietZone Acoustic Wall Framing has been tested in accordance with ANSI/UL263, ASTM E 119 and NFPA51 and is listed in the UL (Design No. U368) Fire Directory with a 1-hour fire rating classification (Always follow UL fire directory guidelines).

Two layers 5/8" thick Type X or C gypsum board or 1/2" thick Type C gypsum board is required on both sides of the acoustical wall framing. QuietZone Acoustic Batts are required to fill the stud cavities in both 2 x 4-stud and 2x6-stud construction. Filling the wall cavity with QuietZone Acoustic Batts also provides fire stopping in lieu of conventional wood blocking. See QuietZone Acoustic Wall Framing Architectural Specifications for more information.
 
Load Bearing Acoustical Non Fire Rated Performances
STC Performance Ratings - Single Layer Type X or Type C Gypsum Board
2 x 4 QZ Framing & QZ Batts Wall Depth STC
16" o.c. 1/2" gyp  4-5/8" 49
24" o.c. 5/8" gyp  4-7/8" 50

 
2 x 6 QZ Framing & QZ Batts Wall Depth STC
16" o.c. 1/2" gyp  6-5/8" 52
24" o.c. 5/8" gyp  6-7/8" 54

 
Load Bearing Acoustical Fire Rated Performances
STC Performance Ratings - Double Layer Type X or Type C Gypsum Both Sides
2 x 4 QZ Framing & QZ Batts Wall Depth STC Fire Rating
16" o.c. 1/2" gyp  5-5/8" 57 1 hour
24" o.c. 5/8" gyp  6-1/8" 58 1 hour

 
2 x 6 QZ Framing & QZ Batts Wall Depth STC Fire Rating
16" o.c. 1/2" gyp  7-5/8" 60 1 hour
24" o.c. 5/8" gyp  8-1/8" 63 1 hour