Owens
Corning World Headquarters
One Owens Corning Parkway
Toledo, OH 43659
Toll-Free: (800) GET-PINK
Web site: http://www.owenscorning.com
QuietZone Acoustic Wall Framing
Designed to replace conventional
wall framing in noise control applications, QuietZone Acoustic Wall Framing
combines two sections of Trus Joist TimberStrand®
LSL connected by several acoustically resilient metal clips. This framing
allows walls to be built with better STC ratings, while maintaining nominal
wall depths. Therefore, walls can be installed at a lower cost than alternative
construction techniques such as resilient channels or staggered studs.
Product Specifications - Maximum Vertical Load (plf) Interior Walls Only | |||||||
Wall
Height |
Member
Length |
On-Center Spacing |
On-Center Spacing |
||||
12" | 16" | 24" | 12" | 16" | 24" | ||
8' | 92-5/8" | 1204 | 837 | 479 | 2365 | 1774 | 1183 |
9' | 104-5/8" | 892 | 607 | 331 | 2365 | 1774 | 1183 |
10' | 116-5/8" | 671 | 446 | 227 | 2365 | 1774 | 1183 |
12' | 144" | 1742 | 1203 | 680 | |||
14' | 168" | 1179 | 791 | 414 |
Fire Safety and Applicable Standards
QuietZone Acoustic Wall Framing has been tested in accordance with ANSI/UL263, ASTM E 119 and NFPA51 and is listed in the UL (Design No. U368) Fire Directory with a 1-hour fire rating classification (Always follow UL fire directory guidelines).
Two layers 5/8" thick Type X or C
gypsum board or 1/2" thick Type C gypsum board is required on both sides
of the acoustical wall framing. QuietZone Acoustic Batts are required to
fill the stud cavities in both 2 x 4-stud and 2x6-stud construction. Filling
the wall cavity with QuietZone Acoustic Batts also provides fire stopping
in lieu of conventional wood blocking. See QuietZone Acoustic Wall Framing
Architectural Specifications for more information.
Load Bearing Acoustical Non Fire Rated Performances | ||
STC Performance Ratings - Single Layer Type X or Type C Gypsum Board | ||
2 x 4 QZ Framing & QZ Batts | Wall Depth | STC |
16" o.c. 1/2" gyp | 4-5/8" | 49 |
24" o.c. 5/8" gyp | 4-7/8" | 50 |
2 x 6 QZ Framing & QZ Batts | Wall Depth | STC |
16" o.c. 1/2" gyp | 6-5/8" | 52 |
24" o.c. 5/8" gyp | 6-7/8" | 54 |
Load Bearing Acoustical Fire Rated Performances | |||
STC Performance Ratings - Double Layer Type X or Type C Gypsum Both Sides | |||
2 x 4 QZ Framing & QZ Batts | Wall Depth | STC | Fire Rating |
16" o.c. 1/2" gyp | 5-5/8" | 57 | 1 hour |
24" o.c. 5/8" gyp | 6-1/8" | 58 | 1 hour |
2 x 6 QZ Framing & QZ Batts | Wall Depth | STC | Fire Rating |
16" o.c. 1/2" gyp | 7-5/8" | 60 | 1 hour |
24" o.c. 5/8" gyp | 8-1/8" | 63 | 1 hour |